Skip to main content

Building Systems

How Many Cameras and PoE Ports for an Office?

FM Ansivue Engineering CCTV system design team Published 9 min read
Office lobby with a ceiling-mounted dome camera
On this page

“How many cameras do I need?” is the wrong first question, because it invites a rule of thumb that has nothing to do with your building. The useful question is which positions have to be covered and what each position has to prove. Once that list exists, the camera count follows from it, the PoE port count follows from the camera count plus spares, and the recorder channel count follows from both.

This article works through the calculation in that order, because the order is what stops a project from buying a 16-port switch for 12 cameras and then finding that the entrance, the lift lobbies and the loading bay consume the spare capacity before phase two begins. The method works for any commercial building surveillance design where the positions can be walked and listed.

The numbers used are from our own range: 5 MP cameras at 2880 × 1620 holding colour to 0.1 Lux, PoE switches with 120 W, 250 W and 320 W budgets on the PS series, and recorders of 10 to 64 channels with 64 Mbps of ingress bandwidth.

Why count positions rather than square metres?

A rule based on floor area produces a number that is either wasteful or negligent depending on the layout. Position-based counting is slower and correct. Walk the building and mark every point where one of these is true:

  • Access points — main entrance, reception, staff entrance, goods entrance, roof access, plant room doors. These are where identification matters, and where the colour budget belongs.
  • Circulation — lift lobbies on every floor, stairwell landings, and corridors at junctions rather than mid-run. A camera at a junction covers two directions; one halfway down a corridor covers a single direction.
  • Lift cars — the car interior is a separate position from the lobby, and it needs a form factor that suits a small, exposed, vibration-heavy space.
  • Vehicle movement — entry and exit lanes, ramp, deck aisles, and any point where a vehicle can be parked out of sight.
  • Service and high-value areas — loading bay, waste store, server room, cash handling, stores.
  • Perimeter and façade — the building line, rear access, and any ground-floor opening that faces a public route.

Each position then needs a second decision: what it has to prove. “See that something happened” and “identify who did it” lead to different cameras, different mounting heights and different lighting requirements.

What does a worked example look like?

Take a six-floor office building with two lifts, a basement car park and one loading bay. The table below is arithmetic, to show how the count grows from a plan rather than from a formula:

AreaPositions to coverCamera formPoE ports
Main entrance and reception2 — the door and the waiting areaDome, colour at night, two-way audio2
Lift lobbies6 — one per floorDome, ceiling mounted, wide angle6
Lift cars2Compact dome in a vandal-resistant housing2
Corridors and stair landings6 — one junction per floorDome6
Car park4 — entry lane, exit lane, ramp and deckDome inside, bullet or PTZ for the ramp run4
Loading bay and waste store2Bullet with the warning light interface2
Server room and stores2Dome2
Perimeter and rear access2Bullet, aimed along the building line2
Total26 positionsMixed forms, colour at the identification points26 ports

How do camera count, PoE ports and budget connect?

Give every camera its own port, and keep spare ports on every switch for the camera that gets added after the first incident plus the access point or intercom that somebody remembers late. Ports, though, are rarely the binding constraint. The budget is.

Our PS series comes in three sizes: 8 PoE ports with 2 gigabit uplinks and a 120 W class budget, 16 ports with a 250 W class budget, and 24 ports with a 320 W class budget. Sizing that budget is a one-line sum:

Σ device power × 1.25 = the PoE budget to specify

A camera’s published power input is DC 12 V 2 A, so the ceiling to plan against is 24 W per camera at full specification, with the fill light, the warning light board and a 2 W speaker accounted for. At that ceiling a 120 W switch covers four cameras, a 250 W switch eight and a 320 W switch ten. That is deliberately pessimistic: the ceiling assumes every load on at once, and a camera in normal night operation draws less. The figure to design against is the measured draw for the model you are ordering, which we will confirm before the order. The budget, not the port count, decides how many switches a building needs.

The practical consequence is that several smaller switches usually beat one large one: each is fed by a single uplink run, which shortens cable routes, and a fault takes out one floor rather than the whole site.

When does extend mode help past the 100 m limit?

Standard PoE over network cable is limited to 100 m per run, and that limit is a design constraint rather than a suggestion. Some of our switches offer a way around it: on the PS series, setting the VLAN DIP switch to ON enables 250 m Extend mode, which drops the link to 10 Mbps and isolates the ports from each other. Ten megabits is ample for a single camera stream, and the port isolation is useful in its own right, but it changes the network topology and it is not the right answer for an uplink. On the 24G02GS-P the VLAN function is fixed at 0–100 m isolation, with no extend mode.

Cable quantity follows the same plan: average run length × number of runs × 1.15 for losses and routing slack, plus the uplink runs from each switch back to the recorder, plus a service loop at every camera — three metres each is a fair allowance for termination.

How do you size the recorder from the ports?

Twenty-six cameras do not belong on a 16-channel recorder, and they do not necessarily belong on a 32-channel one either, because the channel count is only half the limit. Ingress bandwidth is the other half: 64 Mbps is shared across every channel the recorder is recording.

At 26 channels that is about 2.4 Mbps per channel, which is achievable in a low-movement office corridor at H.265+ but not in a busy car park at night where colour, movement and detail all push the bitrate up. The honest options are to plan 16 to 20 channels per recorder rather than filling it, to record lower-priority channels at 3 MP or 2 MP, or to run two recorders — 16 channels and 10 channels, for example.

How much storage, retention and drive budget does it need?

Retention is decided by the same formula used everywhere in this range: GB per day per channel × channels × retention days ÷ 1024 = terabytes required. A 5 MP channel at H.265+ typically sits between 8 and 15 GB per day.

For the worked example, 26 channels at 10 GB per day for 30 days is 26 × 10 × 30 = 7,800 GB, or about 7.6 TB. On the 32-channel recorder that fits inside a single 18 TB bay; at 90 days the same site needs roughly 22.9 TB and both bays. That is the number to put in front of a client early, because it turns a camera count into a budget — and it is much easier to agree a retention period at the start than to explain a second drive purchase later.

What changes the count?

Five things in an office building reliably move the camera count by ten to thirty per cent in either direction. Check each one before the design is priced:

  1. Lighting after hours. If the circuits go off at 19:00 and colour is expected everywhere, the lighting is the problem, not the camera count — and the answer may be fewer colour positions rather than more cameras.
  2. Identification or presence. A car park where faces and plates must be identified needs fewer, better-placed cameras than one where every aisle needs coverage. Presence is cheap; identification is not.
  3. Excluded areas. Toilets, prayer rooms and changing areas should be excluded from the design and noted as excluded, not covered accidentally.
  4. Phasing. If phase two is already funded, buy the recorder channels and switch ports now and the cameras later. Channels are cheap; re-cabling is not.
  5. Plant and roof access. Plant rooms, roof hatches and lift machine spaces are easy to forget and expensive to add after handover.

Send us the floor plan, the retention period you need and whether the lighting stays on after hours, and we will mark the positions, size the PoE budget and recorder channels, and give you the storage number in terabytes. The system planner is the same calculation in a shorter form if you would rather work through it yourself first.

Frequently asked questions

How many cameras does one office floor need?

Count positions, not square metres: lift lobby, two stair doors, the corridor run and the open floor. Most office floors land between twelve and sixteen positions, which is not a coincidence — it is why the 16-port switch is the most common choice.

How many PoE ports should we plan for 22 cameras?

At least 24, in two ways: two 16-port switches with spares, or one 24-port switch. Either way, keep two or three ports free per floor for the access point and the door controller. A 24-port design that uses all 24 ports is a design with no room for the next request.

Does the recorder channel count simply follow the camera count?

Yes, with headroom. A 32-channel recorder for 22 cameras leaves ten channels for the next phase, and the channel count and the drive bays have to be chosen together — a 32-channel recorder that cannot hold the retention you promised is a storage problem, not a channel problem.

How much CAT6 does a building actually need?

Work it out from average run length per floor rather than from floor area: metres per drop × drops, plus service loops. As a planning figure, a sixteen-camera building typically needs roughly 250 to 400 m depending on run lengths, and every run has to stay inside the 100 m limit.

One cabinet or one per floor?

A cabinet roughly every six to eight floors keeps every run inside the 100 m limit; below that, one communications room for the whole building can work. Count the cable metres rather than the floors, and remember that the cabinet is also where the switch and the recorder live.

Do we need a switch on every floor?

Usually yes, for two reasons: it keeps the cable runs short, and it confines a fault to one floor. The exception is a small building with a single central room, where one larger switch is simpler.

How long should we keep the recordings?

Thirty days is the baseline most commercial buildings settle on, with 60 to 90 days on the channels that settle claims — gates, tills, loading docks, stores. Grouping retention by channel group usually buys more useful coverage than spreading the same days evenly.

What usually goes wrong in the first estimate?

Ports are counted but watts are not, and the recorder is sized from the camera count alone. The other common mistake is forgetting the cable: a building is not a diagram, and the average run is what decides the switch positions, the cabinet count and the cable order.
Topics commercial building surveillance poe switch office building cctv system design poe ports

Plan Your CCTV or Video Wall Project